Contra Costa County |
Ordinance Code |
Title 7. BUILDING REGULATIONS |
Division 74. BUILDING CODE |
Chapter 74-4. MODIFICATIONS |
§ 74-4.004. Amendments to CRC.
The 2016 California Residential Code ("CRC") is amended by the changes, additions, and deletions set forth in this chapter and Division 72. Section numbers used below are those of the 2016 California Residential Code.
(a)
Sections R103, R108, R111, R112, R113, and R114 of CRC Chapter 1 (Scope and Application) are deleted.
(b)
In Section R105.2 (Work exempt from permit) of CRC Chapter 1 (Scope and Application), subsection 3 is amended to read:
3.
Retaining walls that are not more than 3 feet in height measured from the top of the footing to the top of the wall and that have a downward ground slope at the bottom of the retaining wall not exceeding 1 (vertical):10(horizontal), unless supporting a surcharge or ground slope exceeding 1(vertical):2(horizontal) or impounding Class I, II, or III-a liquids.
(c)
Table R602.10.3(3) (Bracing Requirements Based on Seismic Design Category) of CRC Chapter 6 (Wall Construction) is amended as follows:
(1)
The title of Table R602.10.3(3) is amended to read:
TABLE R602.10.3(3) f
(2)
Footnote "f" is added to Table R602.10.3(3), to read:
f.
In Seismic Design Categories D0, D1, and D2, Method GB is not permitted and the use of Method PCP is limited to one-story single family dwellings and accessory structures.
(d)
Section R602.10.4.4 is added to Section R602.10.4 (Construction methods for braced wall panels) of CRC Chapter 6 (Wall Construction), to read:
R602.10.4.4 Limits on methods GB and PCP. In Seismic Design Categories D0, D1, and D2, Method GB is not permitted for use as intermittent braced wall panels, but gypsum board is permitted to be installed when required by this section to be placed on the opposite side of the studs from other types of braced wall panel sheathing. In Seismic Design Categories D0, D1, and D2, the use of Method PCP is limited to one-story single family dwellings and accessory structures.
(e)
Appendix H of the CRC is incorporated into the County building code. Appendix A, Appendix B, Appendix C, Appendix D, Appendix E, Appendix F, Appendix G, Appendix I, Appendix J, Appendix K, Appendix L, Appendix M, Appendix N, Appendix O, Appendix P, Appendix Q, Appendix R, Appendix S, Appendix T, Appendix U, Appendix V, and Appendix W of the CRC are excluded from the County building code.
(Ord. No. 2016-22, § III, 11-15-16)